    Ask Lasest Price
    Brand Name : Zhenglan Cable
    Model Number : Nominal Area:800mm2 AAC Overhead Bare Conductor Wire
    Certification : 3C; ISO 9001:2015, ISO 14001:2005, OHSAS 18001:2007
    Payment Terms : L/C, T/T,
    Delivery Time : 15 days
    • Product Details
    • Company Profile

    Overhead Bare Conductor Wire(Nominal Area:800mm2), (AAC,AAAC,ACSR)according to IEC 61089

    Overhead Bare Conductor Wire(Nominal Area:800mm2), AAC Conductor according to IEC 61089(AAC,AAAC,ACSR)


    APPLICATION

    AAC conductor is also known as aluminium stranded conductor. It is manufactured from electrolytically refined aluminium, with a minimum purity of 99.7%.


    STANDARD

    Basic design to BS 215-1 / BS EN 50182 / IEC 61089 / ASTM B 231/B 231M / DIN 48201-5 standards.


    Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.


    CONSTRUCTION

    Concentric lay stranded Aluminium Conductor (AAC) is made up of one or more strands of hard drawn 1350 aluminum alloy. These conductors are used in low, medium and high voltage overhead lines. AAC has seen extensive use in urban areas where spans are usually short but high conductivity us required. The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas. Because of its relatively poor strength to weight ratio, AAC had limited use in transmission lines and rural distribution because of long spans utilized. All aluminium conductors are made up of one or more strands of aluminium wire dep.


    ELECTRICAL PROPERTIES

    density@20ºC2.703 kg/dm
    Temperature Coefficient@20°C0.00403 (°C)
    resistivity@20°C0.028264
    linear Expansivity23 x10 (°C)
    Ambient Temperature-5°C - 50°C
    Wind Pressure80 – 130kg/m
    Seismic Acceleration0.12 - 0.05g
    Isokeraunic level10 – 18
    relative Humidity5 – 100%

    TECHNICAL DATA

    Numbers of WiresFinal modules of ElasticityCoeficient of linear Expansion
    ALKg/mm2Lb/in21/Cº1/Fº
    760008.5 x10623.0 x10-6112.8 x10-6
    1957008.1 x10623.0 x10-6112.8 x10-6
    3757008.1 x10623.0 x10-6112.8 x10-6
    6155007.8 x10623.0 x10-6112.8 x10-6
    9155007.8 x10623.0 x10-6112.8 x10-6



    CONSTRUCTION PARAMETERS

    • IEC 60189

    CodeNominal AreaStrandingOverall DiameterWeightRated StrengthElectrical ResistanceCurrent Rating*
    10107/1.354.0527.41.952.863362
    16167/1.715.1343.83.041.789684
    25257/2.136.3968.44.51.1453110
    40407/2.708.1109.46.80.7158147
    63637/3.3910.17172.310.390.4545195
    10010019/2.5912.95274.8170.2877259
    12512519/2.8914.45343.621.250.2302297
    16016019/3.2716.35439.826.40.1798345
    20020019/3.6618.3549.7320.1439396
    25025019/4.0920.45687.1400.1151454
    31531537/3.2923.03867.951.970.0916522
    40040037/3.7125.971102640.0721603
    45045037/3.9427.581239.8720.0641647
    50050037/4.1529.051377.6800.0577688
    56056037/4.3930.731542.989.60.0515736
    63063061/3.6332.671738.3100.80.0458789
    71071061/3.8534.651959.1113.60.0407845
    80080061/4.0936.812207.41280.0361905
    90090061/4.3338.972483.31440.0321967
    1000100061/4.5741.132759.21600.02891026
    1120*112091/3.9643.563093.5179.20.02581091
    1250*125091/4.1845.983452.62000.02311157
    1400*140091/4.4348.733866.92240.02071226
    1500*150091/4.5850.384143.12400.01931270

    Why you choose us?

    • OEM/ODM services provided;
    • Products comply with GB, IEC, BS, ASTM, DIN, VDE and JIS standards; Customer standard requirments Accepted;
    • Certified to ISO 9001:2015, ISO 14001:2015 and OHSAS 18001:2007;
    • Registered capital of $30 million and factory covers an area of 60,000㎡;
    • Advanced test equipment and procedures, 100% inspection before factory;
    • Enough stocks and the higest efficient shipping time guarranteed;
    • Professional pre-sales and after-sales services provided.
    Quality Overhead Bare Conductor Wire(Nominal Area:800mm2), (AAC,AAAC,ACSR)according to IEC 61089 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Zhenglan Cable Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)